We must know the installation method and precautions of disinfection cabinet
Date:2023-02-231) At the set position of the cabinet, insert the disinfection cabinet body into the square hole smoothly, open the cabinet door, and fix the body on the door surface with six wooden screws, flush.
(2) The disinfection cabinet can be set at the lower part of the cabinet foundation or the upper part of the vertical cabinet as required.
(3) The distance between power socket and disinfection cabinet should be controlled within 2m.
2. Precautions for installation of disinfection cabinet:
(1) The disinfection cabinet shall be installed stably at a place convenient for operation and maintenance and firm (not inclined), and a safe distance of more than 375px shall be kept from the gas appliance and high temperature open fire. [/COLOR]
(2) When embedded in the cabinet and combined with the cabinet, the air inlet [/COLOR] connected with the disinfection cabinet shall be set at the appropriate part of the cabinet embedded to ensure good air feeding. [/COLOR]
(3) It is forbidden to install the disinfection cabinet and power socket in the place where it may be damp or wet with water.
(4) It must be confirmed whether the grounding electrode of the power socket is effectively grounded.
(5) When handling and placing, it should be lifted from the bottom and handled with care. The door handle should not be used as a support for handling.
3. Use method of disinfection cabinet:
(1) When closing the cabinet door, insert the plug into the socket with reliable grounding wire. When the power is connected, the buzzer will beep once. After each press of the button, the buzzer will beep once.
(2) Control panel:
(3) Function description of operation keys:
A. When the power is on, the (upper) key and (lower) key are not started, the display shows the clock timing; When the (upper) key and (lower) key are started at the same time, the display screen will first display the temperature of the lower layer, and then display the remaining time of the countdown of the upper layer after the work of the lower layer is completed; When the upper and lower layers are started separately, the upper layer displays the countdown time and the lower layer displays the temperature in the cabinet.
B. Press the (upper layer) key once, and the upper layer ozone ultraviolet light will work. Press it continuously within 3 seconds to switch the following states:
A. Disinfect for 60 minutes; B. Disinfect for 90 minutes.
C. Press the (lower layer) key once, and the lower layer will start to work at high temperature. When the lower layer temperature reaches 120~130 ℃, it will automatically stop working after 25 minutes.
D. After working for 5 seconds, press the (upper) key to stop the work of the upper layer, and press the (lower) key to stop the work of the lower layer.
E. For time adjustment, the clock adopts the 24-hour system. After pressing the (clock) key for 3 seconds, the clock flashes and enters the time adjustment process. At this time, press the (time adjustment) key to adjust the hour position, and press the (minute adjustment) key to adjust the minute position. After stopping the adjustment for 5 seconds, it will automatically exit the adjustment state.
4. Precautions for use of disinfection cabinet
(1) Before use, please confirm that the installation is in place and reliable, whether the cabinet door is fully pushed to the bottom, cut off the nylon tie on the shelf, and remove the corresponding protective film.
(2) Make sure that the cabinet door is closed before the disinfection cabinet can work, otherwise there will be ozone leakage or ultraviolet radiation and high temperature burns.
(3) The upper ozone ultraviolet disinfection does not have the drying function. The cabinet door can only be opened after the upper work cycle ends for 10 minutes and the lower work cycle ends for 20 minutes to avoid ozone leakage or high temperature burns.
(4) Do not put towels, shoes and non-tableware into the disinfection cabinet for disinfection.
(5) If ozone leakage is found during use, it should be stopped immediately and professional personnel should be notified for maintenance.
(6) After washing the tableware, please pour the water on the surface before putting it into the cabinet and put it on the shelf for one time. Finally, close the cabinet door. Be careful not to put the tableware too tightly, so as not to affect the disinfection effect.
(7) Do not put tableware made of heat-resistant materials such as plastic on the lower layer for high-temperature disinfection; The lower layer is equipped with exhaust holes. Please pay attention not to block the rear exhaust pipe.
(8) If it is found that the ultraviolet light emitted by the ultraviolet lamp tube can be seen directly without any transparent object (such as glass) during use, it should be stopped immediately and the professional personnel should be notified for maintenance.
(9) The surface of ultraviolet light tube and heating tube is made of glass and has poor impact resistance. Pay attention to avoid collision during use and cleaning to avoid damage; In case of damage, the ultraviolet light tube with the same power and wavelength and the heating tube with the same power must be replaced.
(10) The power plug must be unplugged or cut off before maintenance.
(11) If the power cord is damaged, it must be replaced with special cord or special components purchased from its manufacturer or maintenance department.
5. Cleaning and maintenance of disinfection cabinet
(1) Precautions: When cleaning the disinfection cabinet, please shut down the machine and unplug the power plug. Clean the cabinet after it cools down. Do not use gasoline, alcohol and other solvent detergent, which will cause discoloration and surface paint cracking of the disinfection cabinet.
(2) Door cleaning: wipe off the residual detergent with a soft cloth soaked with neutral detergent.
(3) It is forbidden to wash the disinfection cabinet with water.